Select country

SELECT LANGUAGE

Contact us
fluidity.nonstop fluidity
fluidity.nonstop

Quadax Double Flange

Quadax Double Flange is a 4-offset butterfly valve with flanges on both ends for demanding process isolation duties. It combines extreme-temperature capability with a conventional flanged piping interface. The configuration supports straightforward integration where removable flanged installation is preferred. Request a quote for Quadax Double Flange from AxFlow.

Let us help you find the right product from this series

Product features

  • 4-offset sealing geometry → Reduces sealing-surface interference during operation and supports reliable shut-off in demanding duties
  • Pressure classes up to PN 10–160 / ANSI 150–1500 → Extends selection across high-pressure process and utility applications
  • Nominal sizes DN 50–1800 mm / 2–72 in → Covers both compact process lines and large-diameter pipeline duties
  • Published temperature range from −270 °C to +800 °C → Supports cryogenic and high-temperature applications with suitable materials
  • Flanges on both ends → Matches the series to its intended piping and installation concept
  • Metal-seated valve concept → Supports duties where elastomeric seat materials may not suit the process temperature
  • Bi-directional shut-off capability in the Quadax platform → Gives designers flexibility when defining flow and isolation strategy
  • Multiple body and trim material options → Supports duty-specific selection for demanding media and temperature conditions
  • Actuation can be matched to the application → Supports automated isolation and defined fail-position requirements
  • Service and selection support from AxFlow → Helps align valve, actuator and materials with the actual operating duty

Product description

Quadax Double Flange is intended for demanding isolation duties in industries such as chemicals and petrochemicals, cryogenic service, oil and gas, hydrogen, power generation, district heating and industrial gases. The series is relevant where reliable shut-off must be maintained across wide temperature and pressure ranges and where valve selection is critical to process continuity.

The valve uses Quadax's 4-offset geometry, which separates the sealing surfaces during opening and closing and supports controlled metal-seated shut-off under demanding process conditions. Flanges on both ends provide a conventional bolted connection to the pipeline, making the valve suitable where installation, removal and alignment through standard flanged interfaces are important maintenance considerations.

Current Quadax data specifies a 4-offset design, a pressure range of PN 10–160 / ANSI 150–1500, nominal sizes of DN 50–1800 mm / 2–72 in, and flanges on both ends. The published temperature range extends from −270 °C to +800 °C with suitable configuration and materials. These are series limits and the permissible combination for a specific valve depends on size, materials, pressure class, actuator and process conditions.

The double-flange arrangement supports planned removal from the line without cutting welded pipework, which can simplify major maintenance activities when sufficient isolation and lifting access are available. Correct actuator sizing, material selection and flange-class matching remain essential. AxFlow can support selection, actuator matching and service planning for the actual medium and duty.


Quadax Double Flange is used for demanding process and pipeline isolation where pressure, temperature and shut-off reliability are important. Typical Quadax application areas include chemicals and petrochemicals, cryogenic service, oil and gas, hydrogen, power generation and industrial gases. AxFlow can help assess whether this configuration suits the actual duty.
Current Quadax data lists ratings up to PN 10–160 / ANSI 150–1500 for this configuration. The published temperature range is −270 °C to +800 °C with suitable materials and configuration. The allowable combination must be checked for the selected size, material, actuator and process conditions.
The current published nominal-size range is DN 50–1800 mm / 2–72 in. Availability within that range depends on the selected pressure class and configuration. AxFlow can help identify the appropriate valve size and specification for the required flow path and piping standard.
The 4-offset geometry is intended to separate the sealing surfaces during valve movement and control contact at shut-off. This supports metal-seated isolation across demanding pressure and temperature conditions. Final suitability still depends on the selected materials, trim and operating duty.
Yes, AxFlow can support selection of Quadax Double Flange, including the valve configuration, actuator and duty-specific materials. Selection should consider medium, pressure, temperature, line size, connection standard and required fail position. AxFlow can also support service and spare-parts planning for the installed valve.