Carolina Components Sampling systems
SubCategory:
Manufacturer: CarolinaComponentsGroup
Industry: Pharmaceutical
Product features
- Individual and multi-sampling assemblies → match the number of required sampling points
- Tube options of 15 and 50 mL → select a container for small samples
- Bag manifolds with five bags of 50 to 500 mL each → plan repeated collection of larger samples
- Polypropylene, polystyrene and ULDPE container options → match sample and analytical requirements
- Sterile and non-sterile versions → specify the required delivery condition
- Closed-system design → limit exposure during sampling
- Manufacture in ISO Class 7 cleanrooms → support controlled manufacturing requirements
- USP Class VI and animal-component-free materials → support material qualification
- Standard and customised configurations → adapt to the sampling plan
- Aseptic connection options including TPE welding → integrate with compatible process interfaces
Carolina Components Sampling systems is a range of FlowLinX closed sampling assemblies for pharmaceutical production. The systems are intended for cell culture, fermentation, chromatography and sterile fluid transfer. Individual and multiple-container configurations support different sampling plans.
The closed configuration is available as a single sampling unit or as a manifold with multiple containers. The manufacturer documents polypropylene and polystyrene tube assemblies in 15 and 50 mL sizes, and ULDPE bag manifolds with five bags of 50, 100, 250 or 500 mL each. Manufacturing takes place in ISO Class 7 cleanrooms and materials are documented to USP Class VI. Sterile and non-sterile articles are listed, with a sterility assurance level of 10⁻⁶ available for designated configurations.
Define the sample volume, frequency, container material, connection method and handling requirements at each sampling point. Consider how representative samples will be obtained and how the receiving container is separated from the main process without compromising the validated procedure.
Consider the hold time between sample collection and analysis, including whether the sample requires further transfer or a specific storage condition. Choosing the receiving container together with the sampling connection can reduce unnecessary handling steps.
A closed sampling layout can limit exposure of the fluid path during sample collection. Multiple sample containers can simplify planned sampling sequences, while a documented connection and disconnection procedure helps reduce operator variation. Evaluate the cost per sample alongside preparation work and the potential impact of a compromised batch. Contact AxFlow for product selection and availability.