Select country

SELECT LANGUAGE

Contact
fluidity.nonstop fluidity
fluidity.nonstop

RONDS RH505

RONDS RH505 is a wireless vibration and temperature sensor for condition monitoring of rotating machinery, helping maintenance teams capture machine-health data without signal cabling. Request a quote for RONDS RH505 from AxFlow.

Let us help you find the right product from this series

Key product features

  • 2 Hz-20 kHz vibration response -> Supports machine-health trending and detailed vibration analysis.
  • +/-50 g peak vibration range -> Captures demanding machine vibration across a broad measurement range.
  • Integrated temperature measurement -> Adds a second condition indicator for bearings and rotating equipment.
  • Wireless Zigbee communication -> Reduces signal-cabling requirements between sensor and collector.
  • 8.5 Ah battery -> Supports long-term wireless monitoring with reduced routine intervention.
  • IP68 enclosure -> Protects the sensor against dust and water in demanding industrial environments.
  • Waveform length up to 128K -> Provides detailed data for spectrum and waveform diagnostics.
  • Optional ATEX and IECEx certification -> Supports appropriately configured installations in hazardous areas.
  • Integrated sensor and antenna -> Simplifies installation at distributed measurement points.
  • RONDS system integration -> Connects vibration and temperature data to a wider predictive-maintenance workflow.

Product Description

RONDS RH505 is intended for wireless condition monitoring where vibration and temperature trends are required without installing signal cabling to every measurement point. It is suitable for pumps, motors, fans, gearboxes and other rotating machinery where changes in vibration behaviour can support condition-based maintenance planning.

The sensor combines a piezoelectric vibration channel with temperature measurement and wireless data transmission to compatible RONDS collection infrastructure. Current RONDS specifications give a vibration frequency response of 2 Hz to 20 kHz, a peak vibration range of +/-50 g, waveform lengths up to 128K and IP68 ingress protection.

RONDS specifies an 8.5 Ah lithium-thionyl-chloride battery and Zigbee communication. Current documentation also lists ATEX and IECEx options with Ex ia IIC T4 marking for Zones 0, 1 and 2, so hazardous-area suitability can be evaluated against the exact project configuration.

Wireless installation can reduce cabling work and make permanent monitoring practical across dispersed assets, while the broad vibration bandwidth supports both trending and diagnostic analysis. AxFlow can support sensor and monitoring-system selection, integration planning and service requirements. Contact AxFlow to confirm the correct RH505 configuration for the machine, environment and monitoring strategy.


Construction

Height
94
Lenght
46
Width
46

Performance

Max. Temperature
70 Celsius
Min. Temperature
-40 Celsius

Certificates

Cert-image

CE Marking

RONDS RH505 measures vibration and temperature for condition monitoring of rotating machinery. Its piezoelectric vibration channel covers 2 Hz to 20 kHz with a +/-50 g peak range. The data can be used for trending, alarms and vibration diagnostics in a compatible RONDS monitoring system.
RH505 is suited to pumps, motors, fans, gearboxes and other rotating assets where wireless monitoring is practical. Its IP68 construction supports installation in demanding industrial environments. AxFlow can help assess measurement points, mounting and communication requirements for the application.
RONDS lists ATEX and IECEx-certified RH505 configurations with Ex ia IIC T4 marking. Suitable versions are documented for Zones 0, 1 and 2. The exact certification and installation requirements should be confirmed for each project.
RH505 uses Zigbee wireless communication to transmit measurement data to compatible RONDS collection equipment. This reduces the need to run signal cables to each sensor location. Wireless performance still depends on plant layout, obstructions and the selected collector configuration.
Selection should consider machine type, relevant fault frequencies, measurement position, hazardous-area classification and wireless network layout. The sensor must also be matched with suitable RONDS data-collection and analysis infrastructure. Contact AxFlow for product selection, integration support and availability.
SIA AxFlow