Select country
Contact us
fluidity.nonstop fluidity
fluidity.nonstop

Waukesha Cherry-Burrell W80

Waukesha Cherry-Burrell W80 is an aseptic single-seat valve series with a stem-flush adapter that provides a liquid or steam barrier around the valve stem. It is used where aseptic shut-off, divert or tank functions require controlled sealing around the stem area. W80A adds sterile flushing of the body-to-adapter seal. Request a quote for Waukesha Cherry-Burrell W80 from AxFlow.

Let us help you find the right product from this product line

Product features

  • Stem flush adapter → Provides a liquid or steam barrier around the valve stem for aseptic processing
  • W80A sterile flush of the body-to-adapter seal → Extends the aseptic barrier compared with standard W80
  • O-ring positioned close to the product zone → Minimizes crevices at the adapter-to-body transition
  • Same installation dimensions as W60 platform → Simplifies evaluation for upgrade or replacement
  • Multiple valve functions → Support shut-off, divert, tank-outlet and throttling variants
  • 3-A certification → Provides verified documentation for hygienic applications where required
  • CE certification → Provides verified documentation for relevant European conformity
  • ISO 9001 certification → Confirms the manufacturer-stated quality-system certification for the series
  • Compatibility with WCB control tops → Supports automation and position feedback
  • AxFlow aseptic valve selection support → Helps check barrier media, valve function and process requirements before quotation

Product description

Waukesha Cherry-Burrell W80 is selected for aseptic process lines where the valve stem area requires a liquid or steam barrier in addition to normal single-seat valve functionality. The platform supports shut-off, divert, tank-outlet and regulating duties in applications where aseptic integrity, cleaning and service access are important.

The W80 stem-flush adapter seals around the valve stem and provides the barrier medium. The W80A version adds sterile flushing of the body-to-adapter O-ring, extending the aseptic barrier compared with the standard W80 arrangement. The adapter is designed as a direct replacement for the standard W60 adapter while maintaining the same overall installation dimensions.

Verified manufacturer information lists 3-A, CE and ISO 9001 certification and identifies model functions including W81 shut-off, W82 divert, W84 tank outlet and additional throttling and HTST variants. Final selection must confirm the required barrier medium, elastomers, temperature, pressure and valve function for the specific process.

Using a common dimensional platform can simplify evaluation when an aseptic upgrade is required, but compatibility must be verified for the installed valve and process. Correctly specified flush media and seals are critical to the cleaning and aseptic strategy. AxFlow can support configuration review, service and spare-parts planning.


Waukesha Cherry-Burrell W80 is intended for It is used where aseptic shut-off, divert or tank functions require controlled sealing around the stem area. It is based on Waukesha Cherry-Burrell process equipment series technology and should be matched to the actual process duty. AxFlow can support selection and availability checks for the required application.
Waukesha Cherry-Burrell W80 should be selected by checking the duty point, media behaviour, temperature, cleaning method, connections and any series-specific operating limits. Verified manufacturer information lists 3-A, CE and ISO 9001 certification and identifies model functions including W81 shut-off, W82 divert, W84 tank outlet and additional throttling and HTST variants. AxFlow can help compare the verified data with the required installation conditions.
Stem flush adapter provides a liquid or steam barrier around the valve stem for aseptic processing. W80A sterile flush of the body-to-adapter seal extends the aseptic barrier compared with standard W80. The final configuration should still be checked against the real process conditions.
For Waukesha Cherry-Burrell W80, integration should be checked against the existing piping or equipment layout, connections, process conditions and cleaning or control requirements. The verified process equipment operating envelope should be compared with the actual duty before replacement or upgrade. AxFlow can support the practical review of configuration and installation requirements.
Yes, AxFlow can support identification of the correct Waukesha Cherry-Burrell W80 configuration and discuss service or spare-parts requirements. Maintenance planning should reflect the process criticality, wear parts, seals or service items relevant to this series. Contact AxFlow for availability, product selection and a quote.
Eoin Cahill
Water & Wastewater, Power generation, Construction & Mining
Brian Coleman
Food & Beverage Sectors.
Brajan Saraci
Pharmaceutical, BioPharma, Chemical and Petrochemical Sectors